Read Decimal Point Position For Display; Write Linearity Calibration - Excell Wireless Platform Service Manual

Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
Execution conditions for these
commands

12-1-12. Read Decimal Point Position for Display

Write UUID E812 handle (Hex) with the following command(s):
Calibration Command (Hex)
99
After the above 'Read' command set is successfully written to the UUID E812 handle, there will be
return values (Hex data) after reading the UUID E812 handle, such as the following:
99 02 06 GG
GG: 1-byte decimal point position for display; please refer to 12-1-11 Write Decimal Point Position for
Display.
If the 'Write' operation has failed, reading UUID E812 handle will instead return 99 02 7F .... (please
refer to 12-1-39 Return Read & Write Status)
Execution conditions for these
commands

12-1-13. Write Linearity Calibration

This 47(Hex) sub-command set can be written only when Calibration Mode is enabled.
Write UUID E812 handle (Hex) with the following command(s):
Calibration
Length
Sub-Command
Command
(Hex)
(Hex)
(Hex)
99
0B
47
Read UUID E812 handle, which will return 99 02 7F .... (please refer to 12-1-39 Return Read & Write
Status).
Example : We want to calibrate empty load, 1/2 full capacity load, and full capacity load. Therefore
TT = 3, NN = 1,2,3; "NN = 1" denotes empty load; and so on...
Suppose empty load Read 's AD value after filtering = 2000 (regarding acquisition of AD value after
filtering, please refer to 12-1-1. Temporarily Switch E813 Notify Output Formats):
1/2 of full capacity load Read 's AD value after filtering = 102000
Full capacity load Read 's AD value after filtering = 202000
TM
Calibration Mode
Executable
Length (Hex)
01
Calibration Mode
Executable
Type A Data 10
'Write' Description
bytes (Hex)
NN: Nth Linearity Calibration Point (1~4) (First
point : must be empty load)
TT: Linearity Calibration Point count (2~4)
NN TT KK KK KK KK
(minimum 2 points (empty load and full
00 00 00 00
capacity load), maximum 4 points)
KK: AD value for corresponding Nth Linearity
Calibration Point
43
Normal Mode
Not executable
Sub-Command (Hex)
06
Normal Mode
Executable
ZSME000000026