Section Ten Checking Operation Of Fire (Installation Instruction) - Infinity 890 FL Owner's Manual

Table of Contents

Advertisement

In the event of replacing fuel bed components please use only the specified number of components as illustrated. Only use fuel
bed component provided for this appliance. In the interest of safety and efficiency of your appliance when replacing the fuel bed
it is essential that the existing fuel bed be removed and the new components are replaced correctly as a complete set.
Lay fuel bed as described under Users Section.
Warning:
It is important that the fuel bed components are positioned as shown in these instructions.
If the fuel bed components are not positioned correctly this may result in damage to the glass.

SECTION TEN Checking Operation of Fire (installation instruction)

REFIT GLASS PANEL AND FIREPLACE FRAME COVERS – refer to section 3
CHECKING FOR COMBUSTION PRODUCTS CLEARENCE
IMPORTANT:-The smoke test must be carried out with
the fire starting from cold.
Light the fire and leave at maximum input.
Close all the doors and windows.
After five minutes fit the smoke match in a holder
and position as illustrated with the head of the
match just inside the test opening.
Run the match along the top edge All smoke
must be drawn into the test opening if the
clearance is satisfactory.
If spillage occurs wait a further five minutes and
repeat the test.
Repeat the test with doors open and with any
extractor fans in other rooms in operation.
If spillage is detected the cause must be discovered and the fault corrected, if the fault cannot be corrected,
disconnect the fire from the gas supply and seek expert advice. Spillage can be caused by a restriction in the
flue system, down draught or insufficient ventilation into the room where the fire is installed.
ADVISE CUSTOMER THAT:
The glass front of this fire acts as a dress guard, conforming to BS 1945 (1997) and satisfies the heating
appliance regulations (1991) however; a fireguard conforming to BS6539 (1997) must be used to protect
young children, the elderly, or infirm.
The curing effect of heating the logs and other refractory components will cause an initial odour. This is due
to the starch used in the manufacturing process and is non-toxic.
Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all the loose
logs have been removed.
The appliance should be serviced annually by a competent person in accordance with these instructions and
the appliance checked for spillage in accordance with the method detailed in these instructions.
Demonstrate changing the batteries.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting of the glass
panel for cleaning. Refer to the user section of this booklet.
If ventilation is fitted for any reason it must be checked regularly to ensure freedom from obstructions.
Hand these instructions over to the user along with the spare batteries and glass removal tool.
22
LT5845 (ISS 15)

Advertisement

Table of Contents
loading

Table of Contents