3. Firefighters arrive at the site and extinguish the fire.
4. After the fire is extinguished, set up a warning sign to isolate the area and spray water to
reduce the battery temperature to the room temperature±10°C. (You can use an infrared
thermometer or thermal imager.)
5. Observe the batteries for 24 hours and ensure that there is no sign of temperature rise
before removing the batteries. (Only professionals are allowed to remove the batteries.)
6. After removing the batteries, move them to a safe place (an open and safe outdoor place is
recommended), place them in the fire sand box or salt water. These operations must be
performed by professionals who must take insulation measures, such as wearing insulated
gloves, insulated shoes, and personal protective equipment (PPE).
7. After the battery fire is extinguished, if there is no potential risk onsite, the battery must be
handled and recycled by professionals in accordance with local laws and regulations.
8.3 Soaking
If the battery pack is wet or submerged in water, cut off all power switches on inverter side, no
further access. Contact Pytes or an authorized dealer for technical support.
8.4 Battery Falling or Strong Impact
DANGER
If a battery is dropped or violently impacted during installation, it may become faulty and
cannot be used. Using a faulty battery will cause safety risks such as cell leakage and electric
shock.
If a battery has obvious damage or abnormal odor, smoke, or fire occurs, evacuate the
personnel immediately, call emergency services, and contact the professionals. The profes-
sionals can use fire extinguishing facilities to extinguish the fire under safety protection.
If the appearance is not deformed or damaged, and there is no obvious abnormal odor, smoke,
or fire, contact the professionals to transfer the battery to an open and safe place, or contact a
recycling company for disposal.
9 Technical Specifications
Product
System Working Voltage Range
System Working Current
Monitoring Communication
Battery Communication
External Communication
Self-consumption Power
Dimensions (W*D*H)
Weight
Protection Rate
Battery Control Unit
200~870V
50A
RS232
CAN, RS485
CAN, RS485, Dry Contact, WiFi
7.56W
484*510*140mm
13.3 kg
IP20