Table 1.13: SW5-3 & SW5-4: BMC, SIO & RTM COM2 selections
BMC to RTM (Default)
SIO to RTM
SIO to BMC
When COM2 is not used as a console interface, it is used to communicate BMC infor-
mation via the onboard SIO COM2 or RTM COM2. SW5-3 and SW5-4 determine
whether COM2 is routed via SIO COM2 or RTM COM2. Three modes are available.
BMC to RTM COM2 is the default.
Table 1.14: SW6 IPMI programming setting
BMC firmware programmable
ON OFF ON OFF ON ON
Default
BMC to console
OFF ON OFF ON OFF OFF
When COM2 is connected to the BMC, the BMC firmware can be re-programmed by
setting switch 6 to "BMC firmware programmable" mode.
Table 1.15: SW7 - Master/Drone mode setting
Default
Master
ON ON
Drone
OFF OFF
The MIC-3392 default setting is Master.