OneAdvisor-800 Portable Network Tester
QUICK CARD
C O N F I G U R E F T TA O T D R ( C o n t i n u e d )
Configure Report (Figure 11 below) settings as follows:
7.
►
Set Dir Naming to Current_Dir. or select the item and create a new directory.
►
Set Filenaming as desired and check the preview of the file name just below.
►
Set File Content to All Traces.
►
Set Auto Store to Confirm if Alarm=fail.
►
Set Report as to PDF.
►
Set Report Layout to Standard if you are using Job Manager OR if you want one per fiber
measured. Set Report Layout to Consolidated if not using Job Manager and a single PDF
report for many fibers is desired.
S TA RT T E S T
Press the
soft key to start the test.
1.
The OTDR will perform an auto-configuration, Connection Check, and Acquisition on each wavelength.
2.
►
If the Connection is Bad, repeat steps 1 through 7 on page 2, to ensure the patch cable is clean
and undamaged.
►
Passing results will be auto-stored to the current directory.