OneAdvisor-800 Portable Network Tester
QUICK CARD
C O N F I G U R E F T TA O T D R ( C o n t i n u e d )
Configure Setup > Analysis (Figure 9 above) settings as follows:
5.
Set BBU Jumper to Yes if there is a BBU Jumper Cable between the Launch Cable (such as a
ground based OVP between the BBU and the tower) and Trunk Cable;
Set BBU Jumper to No if the Launch Cable is directly connected to the Trunk Cable.
Set RRU Jumper to Yes if there is a Junction Box/OVP/Squid at the top of the tower between
the Trunk Cable and RRU;
Set RRU Jumper to No if there is no Junction Box or no RRU Jumper.
Set Mode to Construction if there will be a loopback cable and/or receive cable employed.
Set Loopback Cable to Yes if there is a Loopback planned to test up and back down the tower;
Set Loopback Cable to No if there will not be a loopback employed.
Set Launch Cable End to Event 1 (always employ a launch cable: 20m recommended)
Set Receive Cable Start to Event 1 if a receive cable will be employed
Configure Link Description (Figure 10 below) settings as follows:
6.
Set Base Station ID to the Test Location or BBU Identifier.
Set RRU ID to the RRU Identifier or the Cable Identifier or sector (e.g. Alpha, Beta, Gamma).
Set Fiber Code to the fiber number and polarity using the up and down arrows.
Set Change Fiber Nbr to Increment.
Set Distance Unit to feet or meters as desired.
Enter the Technician ID and Job ID as needed, or they could come from Job Manager.
OneAdvisor-800 Portable Network Tester
Figure 10: Setup example - Link Description