Environmental specifications
Space requirements
Printer controller placement
XEROX DOCUPRINT 4050/4090 IPS INSTALLATION PLANNING GUIDE
Heat dissipation specifications for the 4050/4090 IPS controller are
shown in the table below.
For recommended environmental ranges for the printer work area,
refer to the "Printer specifications and requirements" chapter of this
guide.
Table 5-3.
Heat dissipation specifications for the 4050/4090
IPS controller
Heat dissipation
The printer controller consists of the Sun workstation and, for
channel-attached systems, the HCU. This section provides
recommendations for placement of controller hardware components.
For printer component space requirements, refer to the "Printer
specifications and requirements" chapter of this guide. Contact your
service representative if you have questions not specifically
addressed in this guide.
You should consider the following factors when deciding where to
place the DocuPrint printer controller:
•
Adequate work space and service clearance around the
equipment
•
Proximity to electrical and network connectors
•
Security of the work area. You may need to place the system in
an area where you can restrict access to it.
The printer controller consists of the Sun workstation and, for
channel-attached systems, the HCU. You must supply a table or
desk as a work surface for both the printer controller and the HCU.
The top of the table(s) must provide at least 36 by 36 inches / 91 by
91 cm of space for each component, to allow enough space for the
components and cables, as well as for service access.
Refer to the "Printer controller specifications and requirements"
summary table at the end of this chapter to make sure the tables you
supply can support the weight of the printer controller hardware
elements and of the HCU, and that they are suitable for the intended
use.
Warning: The printer controller must be positioned within the line-
!
of-sight of the printer for safety purposes while servicing the
equipment.
!
CONTROLLER SPECIFICATIONS AND REQUIREMENTS
Processor
Monitor
1,100 BTU per hour
408 BTU per hour
5-3