Lindy IPower Switch 4 DIN S Pro User Manual page 54

Table of Contents

Advertisement

Specifications
For devices with only one phase, the phase is set to zero in the formula.
Examples:
"Power Active" for 1st line sensor and 3rd phase: 0x400 + 0 * 0x120 + 2 * 0x60 + 1 * 2
= 0x4C2
"Voltage" for 2nd line sensor and single phase device: 0x400 + 1 * 0x120 + 2 * 2 =
0x524
"Power Angle" for 4th port sensor and single phase device: 0x3a00 + 3 * 0x120 + 6 * 2
= 0x3d6c
Offset
Sensor Field
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Whether the measured values "Residual Current" and "Neutral Current" are sup-
ported depends on the respective device model. For measured values such as "Neut-
ral Current", which are independent of the phase, the same value is returned for all
phases.
· Read Device Identification (0x2B / 0x0E)
Returns manufacturer name and device identification:
Request Code
MEI Type
Read Dev ID code
Object Id
Response Code
MEI Type
Read Dev ID code
Conformity Level
Absolute Active Energy
Power Active
Voltage
Current
Frequency
Power Factor
Power Angle
Power Apparent
Power Reactive
Absolute Active Energy Resettable
Absolute Reactive Energy
Absolute Reactive Energy Resettable
Reset Time - sec. since last Energy Counter Reset
Forward Active Energy
Forward Reactive Energy
Forward Active Energy Resettable
Forward Reactive Energy Resettable
Reverse Active Energy
Reverse Reactive Energy
Reverse Active Energy Resettable
Reverse Reactive Energy Resettable
Residual Current Type A
Neutral Current
Residual Current Type B RMS
Residual Current Type B DC
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
0x2b
0x0e
0x01
0x00
0x2b
0x0e
0x01
0x01
54
Unit
Wh
W
V
mA
0.01 hz
0.001
0.1 degree
VA
VAR
Wh
VARh
VARh
s
Wh
VARh
Wh
VARh
Wh
VARh
Wh
VARh
mA
mA
0.1 mA
0.1 mA

Advertisement

Table of Contents
loading

This manual is also suitable for:

32662

Table of Contents