Configuration
actual temperature
during configuration
70 °C
45 °C
20 °C
Action matrix during operation when limit values are exceeded (for given example):
from "above
max"
from "below max"
from "above min"
from "below min" P1 Off + P2 On
Only the switching operations for which actions have been defined, are triggered. If
no "On" or "Off" action is defined for a port, the port can never reach this state by ex-
ceeding sensor values. Unless it is the initial state.
3.6

E-Mail

Enable E-Mail: Activates the e-mail dispatch of messages.
Sender address: The e-mail address of the sender.
Recipient address: The e-mail address of the recipient. Additional E-Mail addresses,
separated by comma, can be specified. The input limit is 100 characters.
SMTP Server: The SMTP IP-address of the e-mail server. Either as FQDN, e.g:
"mail.gmx.net", or as IP-address, e.g: "213.165.64.20". If required, attach a designated
port, e.g: "mail.gmx.net:25".
SMTP server port: The port address of the e-mail server. In the normal case this
should be the same as the default, that is determined by the setting SMTP Connection
Security.
Port 1 Off (above max) + Port 2 On (above min)
Port 1 On (below max) + Port 2 On (above min)
Port 1 On (below max) + Port 2 Off (below min)
to "above max" to "below max" to "above min" to "below min"
-
P1 On
P1 Off
P1 Off
P2 On
32
actions
P1 On
-
-
-
-
P2 On
P1 On + P2 Off
P2 Off
P2 Off
-