PREPARING FOR FIELD LEVEL TESTING: Disassembly Procedure
5. After adhesive is separated, continue to separate the board to board connector in the same
direction. Not from the bottom connector side or antenna side.
6. Remove any remaining adhesive from can side of Main Board and from Keypad Board.
7. Separate LCD Flex Connector to remove Keypad Board.
Board Connector
7.5.6

Removing the Microphone and Seal

Equipment Required: Black Stick.
Preparation: Separate the Front and Back Housings.
1. Insert pointed end of Stick under the sealing face of the mic.
7-10
Adhesive location
(underneath)
Figure 7-7.
Figure 7-8.
Work stick
in and down/
side to side
Adhesive Pad
68P80400P65-O