Entering Test Mode - Motorola iDEN i530 Field Service Manual

Digital multi-service, data-capable portable
Hide thumbs Also See for iDEN i530:
Table of Contents

Advertisement

Table 6-1. Display Screens (Continued)
Name
IMEI/SIM ID
Registr Log
Err/Chan Codes
Current Freq
Dispatch IDs
Band Info
Bandmap
Hardware
Fatal Err/#
Flags
Resets:0
6.1.3

Entering Test Mode

Use this procedure to access test mode.
To enter test mode:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
NOTE: Steps 2 through 7 must be performed quickly (no more than one second between each key
press).
2. Press #.
3. Press *.
4. Press Menu three times.
5. Press the left Scroll key.
6. Press Menu twice.
68P80400P65-O
BASIC LEVEL TEST MODES AND PROCEDURES: Test Modes
Description
Displays the electronic serial number and SIM ID serial number.
The IMEI is the global name assigned to the mobile station at manufacturing time and should
correspond to the serial-number tag of the unit.
The SIM ID is the SIM electronic serial number and should correspond with the number
stamped on the SIM card.
Pressing Trace allows the IMEI/SIM ID to be traced.
Displays the Dispatch Log, Interconnect Log, Packet Data Log, Mobile IP Log, and Phone
Rst Log. Registration Log information is updated when the user deselects and selects the
Registr Log choice.
Displays the physical channel that the unit is connected to or the radio link procedure that is
currently active. Also, displays error codes of errors encountered during normal operation if
Err/Chan codes is On. At power up, the Err/Chan Codes is Off.
Displays the current frequency. Pressing Trace allows the current frequency and band to be
traced.
Displays the Dispatch Group ID affiliated with the unit in the current dispatch-location area.
Also, displays the Dispatch Individual ID affiliated with the unit in the current dispatch
location. Pressing Trace allows the dispatch IDs to be displayed periodically.
Displays primary and secondary bands.
Displays the currently selected regional bandmap. Pressing Trace allows the bandmap to be
displayed periodically.
Displays a screen showing the AFC Offset and Channel Number.
Displays the Fatal Error log. This log contains a count of any fatal errors logged during the
unit's automatic self test. Optioning clear empties the log.
Displays the error log. This log contains any errors logged by the unit software. Pressing
Menu when it appears displays the Clearall screen in which the user can clear all the logged
errors.
Displays the Reset Error log. This log contains any errors logged when the user resets the
unit during operation. The most recent reset appears at the top of the list. Pressing Menu
when it appears displays the Clearall screen in which the user can clear all the logged errors.
6-3