Follett Champion 7 Installation Manual page 15

Ice and water dispenser with chewblet ice machine
Table of Contents

Advertisement

Internal Claris Filter Flushing Sequence
If your dispenser has the internal Claris filter option, the water filter must be flushed prior to use.
To flush the Claris filter, please complete the steps below.
1. Connect power supply and turn on power switch located on back of unit.
2. Place Flushing Hose in 1 gallon (or larger) bucket/container.
3. Rotate flushing valve ¼ turn clockwise so "OPEN" is pointing to the Flush Hose (Fig. 16).
4. Dispense approximately 1.5 gallons of water into a bucket. (If needed, rotate the flushing valve back to the
"CLOSED" position to stop flushing, empty the bucket, then continue flushing until 1.5 gallons has been
collected and discarded).
Fig. 11
Flushing Hose
(insert in bucket)
Water
Inlet
Flush Valve Closed
5. Rotate the flushing valve to "CLOSED" (with "OPEN" pointed to exit port of manifold).
6. Remove plug cap from the end of water reservoir drain tube and lower tube to drain water into bucket.
After the system has been drained of water, replace plug cap in water reservoir drain tube.
7.
Secure tube in holder.
8. Discard water collected in bucket.
9. Reassemble the unit.
Dispense 1.5 gallons into bucket and discard
Water
Water
Outlet
Inlet
Champion Dispenser and Ice Machine - 115 V
Flushing Hose
Flush Valve Open
Water
Outlet
15