HP 8920A Programmer's Manual page 508

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

Chapter 8, Programming The Call Processing Subsystem
Programming The CALL BIT Screen
Handoff
Order
508
See "Reading the CALL BIT Screen Message Fields" on page 511
on how to read the contents of the individual messages.
Syntax
:DSPecifier <'><STD/BITS><'>
:DSPecifier?
Example
OUTPUT 714;"CALLP:DSP?"
OUTPUT 714;"CALLP:DSP 'STD'"
ENTER 714;Build_method$
See "Handoff" on page 475
This field is used to send an order type mobile station control message on the
forward voice channel to the Mobile Station. The orders available are:
Change Power to Power Level 0 - 7
Maintenance (put the mobile station in maintenance mode)
Alert (alert the mobile station)
The
field is a one-of-many selection field. To send an order to the mobile
Order
station position the cursor on the
displayed. Position the cursor on the desired order and select it. Once the selection
is made a mobile station control message is sent to the Mobile Station. The
annunciator will light momentarily while the Test Set is sending the
Access
mobile station control message.
A mobile station must be actively connected on a voice channel to the Test Set
(that is, the
annunciator lit) before attempting to send an order to a
Connect
mobile station.
for programming information.
field and select it. A list of choices is
Order
for information

Advertisement