Clearance Dimensions - Fisher & Paykel RIV3-915 Installation Manual

Professional freestanding cooker
Hide thumbs Also See for RIV3-915:
Table of Contents

Advertisement

C

CLEARANCE DIMENSIONS

A Minimum width of ventilation hood installed above freestanding cooker
B Minimum vertical distance between countertop and cabinet extending above counter
C Minimum clearance from left and right edge of freestanding cooker to nearest vertical
combustible surface
D Minimum clearance from cook surface to:
combustible surface centered above the cook surface
z
combustible covering for ventilation hood centered above the cook surface*
z
non-combustible surface centered above the cook surface*
z
E Maximum overall depth of overhead cabinetry
F Width of cabinetry opening
G Maximum height from floor to countertop:
– for level counter
– with freestanding cooker levelling legs fully extended
H Maximum depth from wall to cabinetry face:
proud control panel
z
CLEARANCE DIMENSIONS
A
D
B
C
G
electrical
F
FRONT
ISO
Note:
RIV3-915
The cooking surface must sit flush or above the adjacent
z
MM
countertop level.
914
If the freestanding cooker is to be placed adjacent to
z
cabinets, the clearances shown are required. The same
457
clearances apply
305
to island installations.
The freestanding cooker can be placed in various
z
positions with respect to the cabinet front, with the
control panel either
762
flush or projecting, depending on the cabinetry depth.
762
The electrical supply should be within the zones shown
z
762
in the following diagrams.
330
Any openings in the wall behind the freestanding cooker
z
and in the floor under the freestanding cooker must be
914
sealed.
Always keep the appliance area clear and free from
z
combustible materials, gasoline and other flammable
908
vapors
933
and liquids.
Do not obstruct the flow of combustion and ventilation air
z
644
to the unit.
E
H
7