CLEARANCE DIMENSIONS

Minimum width of ventilation hood installed above range
A
Minimum vertical distance between countertop and cabinet extending above counter
B
Minimum clearance from left and right edge of range to nearest vertical combustible surface
C
Minimum clearance from cooking surface to:
D
– Overhead cabinet centered above the cooktop (combustible/unprotected) - see notes #1, #2
– Overhead cabinet centered above the cooktop (non-combustible/protected) - see notes #1, #2
– Ventilation hood** centered above the cooking surface
Maximum depth of overhead cabinetry
E
Width of cabinetry opening
F
Maximum height of cabinetry immediately adjacent to the range (from floor to countertop)*
G
Maximum depth from wall to cabinetry face
H
* Depending on the height of the feet adjustment. The cooking surface must sit flush or above countertop level.
** Refer to local/national codes for ventilation requirements.
8
CLEARANCE DIMENSIONS
A
B
B
C
C
COOKING SURFACE
G
G
Electrical & Gas
(see diagrams following)
F
Front
OR30SDI / OR30SCI
inches (mm)
30" (762)
18" (457)
2" (50)
30" (762)
24" (610)
24" (610)
13" (330)
30" (762)
37 1/2" (953)
25 1/4" (641)
A
Note
#1 To eliminate the risk of burns or fire
by reaching over heated surface units,
cabinet storage space located above
the surface units should be avoided.
If cabinet storage is to be provided,
the risk can be reduced by installing a
D
rangehood that projects horizontally a
D
minimum of 5 " (127mm) beyond the
bottom of the cabinets.
C
C
#2
COOKING SURFACE
between the top of the cooking surface
and the bottom of an unprotected wood
or metal cabinet; or
minimum when bottom of wood or
metal cabinet is protected by not less
than ¼"-thick flame retardant millboard
covered with not less than No. 28 MSG
sheet steel, 0.015"-thick stainless steel,
0.024"-thick aluminum, or 0.020"-thick
Electrical & Gas
(see diagrams following)
copper.
F
Note
This range may be installed directly
adjacent to existing 36" (914mm) high
OR30SDE
base cabinets.
If the range is to be placed adjacent
inches (mm)
to cabinets, the clearances shown are
30" (762)
required. The same clearances apply
to island installations.
18" (457)
The range can be placed in various
positions with respect to the cabinet
2" (50)
front, with the control panel either
flush or projecting, depending on the
30" (762)
cabinetry depth.
24" (610)
The electrical supply should
24" (610)
be within the zones shown in the
13" (330)
following diagrams.
Any openings in the wall behind the
30" (762)
range and in the floor under the range
37 1/2" (953)
must be sealed.
Always keep the appliance area clear
25 1/4" (641)
and free from combustible materials,
gasoline and other flammable vapors
and liquids.
Do not obstruct the flow of ventilation
air to the unit.
D
=30" (762mm) minimum clearance
D
=24" (610mm)