Volvo Penta TAD1360VE Operator's Manual page 83

Table of Contents

Advertisement

Bringing Out of Storage
Remove any covers from the engine, air filter
and exhaust pipe.
Fill the engine with the correct quality and
viscosity oil into the engine, as necessary, refer
to Technical Data, Lubrication System. Install a
new oil filter if the filter was not changed during
conservation.
Install new fuel filters and bleed the fuel system.
Check the drive belt(s).
Check the condition of all rubber hoses, and
retighten the hose clamps.
Conservation of the lubrication and fuel systems for more than 8 months' stoppage:
Drain the engine oil and fill up with conservation
oil* to just over the MIN marking on the dipstick.
Connect the fuel suction and return hoses to a 1/3
full jerrican containing conservation oil* and 2/3
diesel fuel.
Bleed the fuel system.
* Conservation oils are sold by oil companies.
47711155 06-2021 © AB VOLVO PENTA
Close the drain taps and install any drain plugs.
Check the coolant level. Top up as necessary.
Connect the fully charged batteries.
Start the engine and warm it up at fast idle with
no load.
Check that no oil, fuel or coolant leakage occurs.
Fill the AdBlue/DEF tank. The solution must
fulfill ISO 22241 standards.
Start the engine and run at a fast idle until about 2
liters (0.6 US gal) of the fluid in the jerrican have
been used. Stop the engine and re-connect the fuel
suction and return lines.
Drain the conservation oil from the engine.
Follow the other instructions on the previous page.
Storage
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tad1361veTad1362veTad1363veTad1364veTad1365ve

Table of Contents