Component fault
1
A
100%
10 h
75 %
20 h
20 %
0%
P
00
18548
A
Engine rpm and torque
B
Time axis
1 A fault is detected and the warning lamp lights up.
2 After 10 hours the engine drops to 75 % power. Ramp-down takes around 25 minutes.
3 If the fault has not been remedied after a further 10 hours, the engine will be limited to 20 % power on re-
start.
4 When the fault is remedied the engine will revert to full power.
5 Depending on the installation, it is possible after the first 20 hours to manually override the system actions
and run the engine at full power for 3 x 30 minutes. After 30 minutes the engine drops to 20% power and
must be restarted to begin the next 30-minute period.