10-5. ERROR STATUS FLAG
When an error (for details, see "9-4. ERROR CODES") occurs ((1)) on the product, the product turns OFF the [Remote
READY] and turns ON the [Error status flag] ((2)).
Turn ON the [Error reset request flag] ((3)) from the master, to turn OFF the [Error status flag] ((4)) and to turn ON the
[Remote READY] ((5)).
Error status flag
(RX007A)
Error reset request flag
(RY007A)
Remote READY
(RX007B)
Error codes
(RWr0006)
Error auxiliary code
(RWr0007)
ON [1]
OFF [0]
ON [1]
(2)
OFF [0]
ON [1]
OFF [0]
(1)
(1)