8-3. REMOTE INPUT AND REMOTE OUTPUT
8-3-1. Address map
● Number of occupied stations: 4 stations
M: Master (PLC) → R: Remote (WGA-680A)
Station
Buffer
No.
address
RY0000
RY0001
RY0002
RY0003
RY0004
RY0005
RY0006
0160
H
RY0007
RY0008
RY0009
RY000A
RY000B
RY000C
RY000D
RY000E
1
RY000F
RY0010
RY0011
RY0012
0161
H
RY0013 to
RY001F
Remote
Name
output
Command processing
request 1
(Reserved)
Command processing
request 2
WRITE/READ
(Reserved)
(Reserved)
(Reserved)
Operation pattern 0
Operation pattern 1
Operation pattern 2
Operation pattern 3
(Reserved)
Value selection 1
(Reserved)
(Reserved)
(Reserved)
ZERO command
RESET command
HOLD command
(Reserved)
NOTE
The buffer address is the value, when the Station number is "1".
R: Remote (WGA-680A) → M: Master (PLC)
Buffer
Remote
address
RX0000
RX0001
RX0002
RX0003
RX0004
RX0005
RX0006
00E0
H
RX0007
RX0008
RX0009
RX000A
RX000B
RX000C
RX000D
RX000E
RX000F
RX0010
RX0011
RX0012
RX0013
RX0014
RX0015
RX0016
RX0017
00E1
H
RX0018
RX0019
RX001A
RX001B
RX001C
RX001D
RX001E
RX001F
15
Name
input
Command processing response
1
(Reserved)
Command processing response
2
WRITE/READ response
(Reserved)
(Reserved)
CPU normal operation
Operation pattern 0 response
Operation pattern 1 response
Operation pattern 2 response
Operation pattern 3 response
Decimal point position 10
Decimal point position 10
Decimal point position 10
Decimal point position 10
Decimal point position 10
[HH] comparator (comparator3)
[HI] comparator (comparator1)
Working properly (Passed)
[LO] comparator (comparator2)
[LL] comparator (comparator4)
(Reserved)
(Reserved)
Detecting
Holding
(Reserved)
(Reserved)
(Reserved)
OVER error (input)
OVER error (indicated value)
Calibration error
Memory error
0
1
2
3
4