6. CC-Link SETTINGS
NOTE
DA output and control output are stopped when the instrument is in function selection mode(F-** is displayed)
or during function setting.
When applying a load, pay attention to overload and control status.
For details of functions, see "4" in the WGA-680A INSTRUMENTATION AMPLIFIER INSTRUCTION
MANUAL. To set the CC-Link, go to the FUNCTION SELECTING mode [F-18] (CC-Link).
FUNCTION
SELECTING mode
F-18
CC-Link
7. BUFFER ADDRESS OF PLC
When the Number of occupied stations is "2" or "4", make sure each PLC (master) has unique address.
The buffer address, assigned to the remote device (WGA-680A), varies with the Station number as follows.
Station
Remote input: RX
number
Address
1
00E0
H
2
00E2
H
3
00E4
H
4
00E6
H
Key operation and product movement in SETTING mode
Display the following items(1), (2), (3)
(1) Number of occupied stations
0: 1 station
1: 2 stations
2: 4 stations (initial value)
(2) Communication speed
0: 10 Mbps (initial value)
1: 5 Mbps
2: 2.5 Mbps
3: 625 kbps
4: 156 kbps
(3) Station number
Range: 01 to 64 (initial value: 01)
Select and change values in items (1), (2), and (3) and
press the SET key.
Remote output: RY
Input RX
Address
RX0000
0160
H
RX0020
0162
H
RX0040
0164
H
RX0060
0166
H
(1) (2) (3)
Remote register: M → R
Output RY
Address
RY0000
01E0
H
RY0020
01E4
H
RY0040
01E8
H
RY0060
01EC
H
M: Master (PLC)
9
Functional description
Selects the number of occupied
stations as the remote device
station.
The address map varies with the
number of occupied stations.
The range of the Station number
varies with the Number of
occupied stations.
01 to 64
Number of occupied stations: 1
01 to 63
Number of occupied stations: 2
01 to 61
Number of occupied stations: 4
Remote register: R → M
Resistor M→R
Address
RWw0000
02E0
RWw0004
02E4
RWw0008
02E8
RWw000C
02EC
R: Remote (WGA-680A)
Resistor R→M
RWr0000
H
RWr0004
H
RWr0008
H
RWr000C
H