10-2. TO WRITE THE PRE-SET VALUES OF THE COMMANDS (BY USING THE REQUEST 2)
To write the pre-set value in the product, set the [WRITE_READ] to "OFF."
When the product turns ON the [Command processing request 2] with the [Command processing request 1],
[Command processing request 2], [Command processing response 1], and [Command processing response 2] are all
OFF, the command writes the pre-set values in the product
(1) With the commands for the operation pattern (for details, see "9-1. COMMANDS FOR THE OPERATION
PATTERN"), enter the operation pattern in the [Operation pattern] of the remote register M → R. You are not
required to set the item with the commands for the general settings and commands for the control input signals.
(2) Enter values in the [Command No.] and [Command data] of the remote register M → R.
(3) Change the [WRITE_READ] of the remote output is OFF.
(4) Change the [Command processing request 2] of the remote output. OFF [0] → ON [1]
(5) Make sure the change of the [Command processing response 2] of the remote input. OFF [0] → ON [1]
Then change the [Command processing request 1] of the remote output. ON [1] → OFF [0]
(6) The product stores the response in the [WRITE_READ response] of the remote input and in the [Command No.
response] and [Operation pattern response] of the remote register R → M.
Command processing
request 2 (RY0002)
Command processing
response 2 (RX0002)
WRITE_READ
(RY0003)
Operation pattern
(RWw000F)
Command No.
(RWw000E)
Command data
(RWw000C to 000D)
WRITE_READ response
(RX0003)
Command No. response
(RWr000E)
Operation pattern response
(RWr000F)
ON [1]
OFF [1]
ON [1]
OFF [1]
ON [1]
OFF [1]
ON [1]
OFF [1]
24
(4)
(3)
(1)
(2)
(2)
(5)
(6)
(6)
(6)