8-2-2. Format of the remote register R → M
● Indicated value_Selection: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E0
The data varies with the remote output [Value selection 1].
MSB
3
L
10
th digit
H
Sign
Indicate the same format with the command data (numerical values).
● Holding value: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E8
Store the indicated values (when in operation) during the Hold mode.
MSB
3
L
10
th digit
H
Sign
Indicate the digits (BCD data) and signs in the same manner as that of the above.
MEMO
Store the holding values (indicated values) in the remote register, based on the following conditions.
● The updating rate is the same value, pre-set in the FUNCTION SELECTING mode [F-21] (Display updating
rate).
● When the display mode is "Hold display mode" in the FUNCTION SELECTING mode [F-04] (Hold mode),
the holding value (indicated value), immediately after turning ON the HOLD command, appears during the
Detecting interval.
● The holding value (indicated value), when selecting the minimum scale in the FUNCTION SELECTING
mode [F-07] (Smoothing), appears.
● Measured value: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02EA
Store the scaled calibration data (the same data during the tracking) of the sensor inputs, irrespective of the Hold
mode.
MSB
3
L
10
th digit
H
Sign
Indicate the digits (BCD data) and signs in the same manner as that of the above.
MEMO
Store the measured values (tracking values) in the remote register, based on the following conditions.
● The updating rate is 4000 times/sec (= sampling rate).
● Not affected by the settings of the FUNCTION SELECTING mode [F-04] (Hold mode).
● Not affected by the minimum scale of the FUNCTION SELECTING mode [F-07] (Smoothing).
● Error code: 4 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E6
Store the WGA-680A error codes.
MSB
All "0"
Indicate the error codes as follows.
0000: None,
0001: Over error (input),
0011: Calibration error,
2
4 bits
10
th digit
4 bits
All "0"
2
4 bits
10
th digit
4 bits
All "0"
2
4 bits
10
thdigit
4 bits
All "0"
4 bits
All "0"
0010: Over error (indicated value)
0100: Memory error
1
4 bits
10
th digit
4 bits
All "0"
1
4 bits
10
th digit
4 bits
All "0"
1
4 bits
10
th digit
4 bits
All "0"
4 bits
All "0"
13
to 02E1
H
H
0
4 bits
10
th digit
4
4 bits
10
th digit
to 02E9
H
H
0
4 bits
10
th digit
4
4 bits
10
th digit
to 02EB
H
H
0
4 bits
10
th digit
4
4 bits
10
th digit
H
4 bits
Error code
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB
4 bits

Advertisement

loading

This manual is also suitable for:

Wga-680a-04Wga-680a-14