10. SETTING PROCEDURES
MEMO
Indicate the buffer address when the No. of occupied stations is "4."
10-1. TO WRITE THE PRE-SET VALUES OF THE OPERATION PATTERN LIMITED DATA (BY USING TRE
REQUEST 1)
The [command processing request 1] writes the pre-set values (comparator values) of the operation pattern limited data.
When the product turns ON the [Command processing request 1] with the [Command processing request 1],
[Command processing request 2], [Command processing response 1], and [Command processing response 2] are all
OFF, the command writes the pre-set values in the product. The [command processing request 1] saves the comparator
values in the specified operation pattern No.
(1) Enter the operation pattern No. in the [Operation pattern] of the Remote register M → R.
(2) Enter the comparator values in the [[HH] comparator value_H/L, [HI] comparator value_H/L, [LO] comparator
value_H/L, [LL] comparator value_H/L] of the Remote register M → R.
(3) Change the [Command processing request 1] of the remote output. OFF [0] → ON [1]
(4) Make sure the change of the [Command processing response 1] of the remote input. OFF [0] → ON [1]
Then change the [Command processing request 1] of the remote output. ON [1] → OFF [0]
(5) The product stores the response in the [Operation pattern response] of the remote register R → M.
Command processing
request 1 (RY0000)
Command processing
response 1 (RX0000)
Operation pattern
(RWw000F)
Comparator values for the operation
pattern (RWw0000 to 0007)
Operation pattern response
(RWr000F)
ON [1]
OFF [1]
ON [1]
OFF [1]
23
(3)
(1)
(2)
(4)
(5)