Reverse Sensor (Erd) - Max Phantom 2000 Installation And Owner's Manual

High traffic commercial brushless dc low profile swing gate operator
Table of Contents

Advertisement

reverse sensor (erd)

The Phantom 2000 is equipped with an ERD Sensor - Electronic Reversing Device (Type A) that functions as the primary
entrapment protection according to UL 325 standards. The gate will reverse direction after encountering an obstruction in
either the OPEN or CLOSE gate cycle.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
THE RELEASE HANDLE CLAMP MUST NOT SLIP when the gate encounters an obstruction.
Limit switches must be learned BEFORE adjusting the ERD Sensitivity.
Ba
tte
ry
E
Vo
lta
1/ 2
ge
F
ON
/O FF
Ba
tte
Re
M A
ry
pl ac
Ba
e
Ba
X B
tte
tte
C -7
ry
TE
ry
Ba
ST
M od
tte
Ba
ul e
ry
tte
ry
Er ro
IN
r
STOP Gate
STOP Gate
Half-way
Half-way
Position gate half-way open and STOP gate.
This gate position will put the most amount of
resistance on the ERD sensor when gate cycles.
Test ERD Sensitivity
Allow the gate to strike an immobile object while OPENING and CLOSING. The gate MUST reverse direction
after striking the object. If it does not, increase the ERD Sensitivity. Repeat this process until the correct
sensitivity is set. If alarm sounds while preforming this procedure, press alarm reset button on control box.
NOTE: When solid gates are installed in unusually high wind areas, ERD sensor can be set to Min to keep
the gate cycling normally in such extreme conditions.
CAUTION:
Minimum sensitivity setting results in gate exerting MAXIMUM force before reversing direction.
36
Adjustments
MC-100
Motor Controller
Turn knob clockwise until
green LED lights up
(Max sensitivity reached) . . .
1
ERD
JOG
JOG
Sensitivity
LEFT
RIGHT
MOTOR OVERLOAD
ERD
Max
Min
Sensitivity
Adjust ERD Sensitivity
Turn knob counter-clockwise
to reduce sensitivity as
needed (LED will turn OFF).
ERD
Sensitivity
Max
M
M
M
M
a
a
ax
x
Min
Sensi
Sensit
Sensitivity
Sens
S
Sen
Sensiti
ensitiv
sitiv
2
CLOSE Gate
CLOSE Gate
CLOSE gate. If ERD sensor triggers, reduce
sensitivity. If sensor does NOT trigger,
sensitivity is set correctly.
Matrix
UL
Edge 1
On Line
Entrap
Power
Limit SW
Edge 2
Photo
INPUTS
On Line
Cell
MC-100 motor controller
ERD
Sensitivity
Max
Min
Sensitivity
A l a
r m
B u
t t o
R e
s e t
n

Advertisement