must be disconnected. If you are just go-
ing to replace a light bulb, then it is
enough to switch off the lights.
- Before disconnecting the battery, switch
off the anti-theft alarm system! Other-
wise you will set off t he alarm.
- When disconnecting the battery, first
disconnect the negative cable and then
the positive cable .
- Before reconnecting the battery, make
sure all electrical consumers are switch-
ed off. Reconnect the positive cable first
and then the negative cable. Never inter-
change the cables - this could start a fire!
- Never charge a frozen or a thawed -out
battery. It could explode! If a battery has
frozen, then it must be replaced. A dis-
charged battery can freeze over at 32 °F
(0
oc).
- Make sure the vent hose is always attach-
ed to the opening on the side of the bat-
tery.
- Never use batteries which are damaged.
Danger of explosion! Always replace a
damaged battery.
A
WARNING
California Proposition 65 Warning:
- Battery posts, terminals and related ac-
cessories contain lead and lead com-
pounds, chemicals known to the State of
California to cause cancer and reproduc-
tive problems. Wash hands after han-
dling.
CD
Note
- Do not disconnect the vehicle battery
when the ignition is switched on or when
the engine is running , otherwise, you will
damage electronic components in the
electrical system.
- If your vehicle is going to stand for a
long period of time without being driven,
protect the battery from "freezing", oth-
erwise it will be damaged and will then
have to be replaced .
Checking
and filling
195
Checking the battery acid level on magic
eye batteries*
The battery acid level in the battery can be
checked through the clear inspection window .
Fig. 148
L uggage compartment : Battery With magic
eye.
On top of the battery, there is a round "win-
dow ". This window (magic eye) changes color
as the battery charge and acid level change.
.. Read and heed all WARNINGS
c:>
,&
in
Working on the battery on page 194
.. Read the acid level from the window on the
battery
c:>
fig. 148 .
Air bubbles in the window can cause an inac-
curate reading . Carefully tap on the side of
the window.
- If the window is green, the battery acid level
is correct.
- If t he window has no color or is bright yel-
low, the battery acid level is too low. Have
the battery tested by your authorized Audi
dealer or a qualified workshop .
- If the window is black, then the battery is
insufficiently charged . Recharge the battery
as soon as possible
c:>
page 196 .
CD
Note
Do not overfill the battery, otherwise bat -
tery acid will overflow through the vent
opening. This can damage the paint and
cause corrosion .

Advertisement