Maintenance
5. Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of
the light source's life and/or mechanical wear. To maintain optimum performance and minimize wear, clean
each lighting product at least twice a month. However, be aware that usage and environmental conditions
could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1. Unplug the product from power.
2. Wait until the product is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
surface/vents.
4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6. Softly drag any dirt or grime to the outside of the transparent surface.
7. Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Do not spin the cooling fans with compressed air. Damage may result.
Torque Measurements
To maintain the IP rating when reassembling the product, use the given torque measurements for each of
the following screws and bolts:
Fixture Parts
Power, USB, and DMX connectors
Back cover
Top cover
Vacuum Test Measurements
Use the IP Tester from Chauvet Professional to ensure the product has been reassembled correctly by
following the information below:
Parameters
Method
Test pressure
Test duration
PASS state leak pressure
STRIKE Array 4C User Manual Rev. 1
Torque Rating (Kgf.cm)
6
6
4
Positive
30 seconds
<0.5 kPa
Torque Rating (lgb.in)
5.20776
5.20776
3.47184
Values
40 kPa
23