Page 2
Edition Notes The STRIKE 1 User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the STRIKE 1 as of the release date of this edition. Trademarks Chauvet, Chauvet Professional, the Chauvet logo and STRIKE are registered trademarks or trademarks of Chauvet &...
Useful information. Any reference to data or power connections in this manual assumes the use of Seetronic IP-rated cables. The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol. STRIKE 1 User Manual Rev. 8...
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it. • In the event of a serious operating problem, stop using immediately. STRIKE 1 User Manual Rev. 8...
This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the user. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. STRIKE 1 User Manual Rev. 8...
Description STRIKE 1 is a big, bold, outdoor-ready blinder powered by an intense 230 W warm white LED source. It is also an awesome strobe and a wide area floodlight. Its IP rated fan keeps it cool enough for use as a wash while IP rated direct power and DMX connections eliminate undesirable whips.
Introduction Product Dimensions 14.96 in 380 mm 14.61 in 371 mm 7.4 in 188 mm 9.25 in 11.69 in 235 mm 297 mm 12.52 in 318 mm STRIKE 1 User Manual Rev. 8...
3. Setup AC Power The STRIKE 1 has an auto-ranging power supply, and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
Setup Multi-Bracket Each STRIKE 1 comes with a Multi-Bracket that allows an array of STRIKE 1 products to be assembled together with ease. Each Multi-Bracket comes with a spacer bar that maintains the horizontal pixel pitch between each STRIKE 1 product, and a spacer that stabilizes the brackets.
Setup Procedure The STRIKE 1 comes with a double-bracketed yoke hat can be attached to the included Multi-Bracket or mounting clamps directly. The user must supply the mounting clamps. Make sure the clamps are capable of supporting the weight of this product. Use at least one mounting point per product. For the Chauvet Professional line of mounting clamps, go to http://www.trusst.com/products.
Setup DMX Linking The STRIKE 1 can link to a DMX controller using a 5-pin DMX connection or a WDMX connection. For more information about DMX, read the DMX primer at: https://www.chauvetprofessional.com/wp-content/uploads/2016/06/DMX_Primer.pdf. Remote Device Management Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally along existing DMX cabling.
When the control panel lock is activated, in order to access the products main programming level, the product will prompt for the passcode. Enter the passcode as described below. Passcode After being prompted to enter the passcode: Press <UP>, <DOWN>, <UP>, <DOWN>, <ENTER> STRIKE 1 User Manual Rev. 8...
Operation Menu Map Refer to the STRIKE 1 product page on www.chauvetprofessional.com for the latest menu map. Main Level Programming Levels Description Selects DMX address (highest channel restricted to DMX Address Address <000–512> personality chosen). 1 Ch 1-channel: dimmer 3 Ch...
Page 16
203 Dimmer speed mode 2 255 Dimmer speed mode 3 (slowest) *Hold the desired Dimmer Speed value for 3 seconds, then release. This changes the Dimmer Mode setting in the menu. STRIKE 1 User Manual Rev. 8...
Go to the Red Shift main level Select On or Off. Master/Slave The Master/Slave mode allows a group of STRIKE 1 products (the slaves) to simultaneously duplicate the output of another STRIKE 1 (the master) without a DMX controller. To set each of the slaves: Go to the Master/Slave main level Select Slave.
Go to the Information main level. Select Fixture Hours, Version, or UID. Factory Reset To reset the product to factory settings: Go to the Reset Factory main level. Select No (to cancel) or Yes (to reset the product configuration). STRIKE 1 User Manual Rev. 8...
7. Gently polish the transparent surfaces until they are free of haze and lint. Always dry the transparent surfaces carefully after cleaning them. Do not spin the cooling fans with compressed air. Damage may occur. STRIKE 1 User Manual Rev. 8...
For warranty terms and conditions and return information, please visit our website. For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration. STRIKE 1 User Manual Rev. 8...