Standalone Configuration

Static Mode

The static mode options under Virtual Color Wheel also include preset color temperatures, a manual
color mixer, and cross-fade speed.

Virtual Color Wheel

To select from the Virtual Color Wheel:
1. Go to the Virtual Color Wheel main level.
2. Select the Virtual Color Wheel option.
3. Select the desired virtual gel color (see the
4. Set the Dimmer value (0–255).

Color Temperature

To select a preset color temperature:
1. Go to the Virtual Color Wheel main level.
2. Select the Color Temperature option.
3. Select the desired color temperature (see the
4. Set the Dimmer value (0–255).

Manual Color Mixer

To manually mix a custom static color:
1. Go to the Virtual Color Wheel main level.
2. Select the Manual option.
3. Select the color to edit (Red, Green, Blue, Amber, or White).
4. Set the value for the selected color (0–255).
5. Repeat steps 3 and 4 until product outputs as desired.

Color X-Fade Speed

The Color X-Fade Speed option creates a fade transition between colors when using colors in the Virtual
Color Wheel or the Color Temperature chart.
1. Go to the Virtual Color Wheel main level.
2. Select Color X-Fade Speed.
3. Select Fade Speed 1–4 (from fast to slow) or Off (to turn off the fade transition between colors).

Auto Show

To select an automatic program:
1. Go to the Auto Show main level.
2. Select the desired auto program (Auto 1–6).
3. Set the Speed value (1–100).

Settings Configuration

Red Shift

With red shift enabled, the color temperature will warm as the dimmer decreases in imitation of a lamp. To
enable or disable the red shift function:
1. Go to the Red Shift main level.
2. Select from On or Off.

Master/Slave

To set the STRIKE Array 4C product to master or slave mode:
1. Go to the Master/Slave main level.
2. Select from Master (sends control signal) or Slave (receives control signal).
Configure all the slave products before connecting the master to the daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave operation
because the controller may interfere with the signals from the master.
Do not connect more than 31 slaves to the master.

Dimmer Curve

To set the dimmer curve:
1. Go to the Red Shift main level.
2. Select from S-Curve, Linear, Square, or Inverse Square.