Bender ISOMETER iso175 Quick Start Manual page 10

Insulation monitoring device for unearthed drive systems (it systems) in road vehicles
Hide thumbs Also See for ISOMETER iso175:
Table of Contents

Advertisement

ISOMETER® iso175
HV-Anschluss
Leitungslänge max. .......................................................................... 2 m
Leitungsquerschnitt .......................................................... AWG 20...24
validierter Kabeltyp .......................................................AlphaWire 5875
Umwelt
Arbeitstemperatur .......................................................... -40...+105 °C
Temperaturzyklus (ISO 16750-4) ........................................................ Ka
Luftfeuchte (rH) .....................................................................0...100 %
Einsatzhöhe ............................................................................ ≤ 3000 m
Klimaklassen nach IEC 60721
Transport (IEC 60721-3-2) .............................................................. 2K11
Langzeitlagerung (IEC 60721-3-1) .................................................. 1K21
Mechanische Beanspruchung nach IEC 60721
Transport (IEC 60721-3-2) ............................................................... 2M4
Langzeitlagerung (IEC 60721-3-1) ................................................. 1M10
Sonstiges
Betriebsart ......................................................................... Dauerbetrieb
Entflammbarkeitsklasse nach ..................................................UL 94 V-0
Durchbiegung ....... max. 1 % der Länge bzw. der Breite der Leiterplatte
Beschichtung ..............................Schutzlack (ELPEGUARD® SL 1307 FLZ)
Gewicht .................................................................................. 37 g ± 3 g
10
iso175_D00415_01_Q_DEEN/11.2023
HV connection
Cable length, max ............................................................................. 2 m
Cable cross section ............................................................ AWG 20...24
Validated cable type ......................................................AlphaWire 5875
Environment
Operating temperature .................................................. -40...+105 °C
Temperature cycle (ISO 16750-4)........................................................ Ka
Air humidity (rH) ....................................................................0...100 %
Altitude ................................................................................... ≤ 3000 m
Classification of climatic conditions acc. to IEC 60721
Transport (IEC 60721-3-2) .............................................................. 2K11
Long-time storage (IEC 60721-3-1) ................................................ 1K21
Classification of mechanical conditions acc. to IEC 60721
Transport (IEC 60721-3-2) ............................................................... 2M4
Long-time storage (IEC 60721-3-1) ............................................... 1M10
Other
Operating mode ....................................................Continuous operation
Flammability class as per .........................................................UL 94 V-0
Deflection ........................... max. 1 % of the length or width of the PCB
Coating .............................. Protective paint (ELPEGUARD® SL 1307 FLZ)
Weight ................................................................................... 37 g ± 3 g