Table 5.1 Environmental Specifications; Table 5.2 Ultraseal 20 Actuator Performance Specifications - Branson Emerson Ultraseal 20 Operating Manual

Table of Contents

Advertisement

5.1
Technical Specifications
5.1.1
Requirement Specifications
The Ultraseal 20 actuator requires compressed air. The factory air source must be "clean
and dry air", that is, without moisture or lubricants. The Actuator requires 70 psi minimum
pressure for operation and cooling, and can require up to 80 psi maximum, depending on
the application. The following table lists environmental specifications for the ultrasonic
welder. The following table lists environmental specifications for the ultrasonic welder.

Table 5.1 Environmental Specifications

Humidity
Ambient Operating Temperature
Storage / Shipping Temperature
Storage Temperature Gradient
Operating Altitude
IP Rating
All electrical input power connections are to the Controller.
5.1.2
Performance Specifications
The following table details some of the performance specifications associated with the
Ultraseal 20 Actuator.

Table 5.2 Ultraseal 20 Actuator Performance Specifications

Height Encoder Accuracy
Max. Tube Diameter
52
Environment
Range
30% to 90% non condensing
+5ºC to +50ºC (+41ºF to +131ºF)
-25ºC to +55ºC (-13ºF to +131ºF)
+15ºC/hour (+59ºF/hour) max
1000 m (3280 ft)
2X
+/-0.05 mm (0.002 in)
12 mm (0.47 in)
DCM00051 REV. 10