Toshiba MMY-MUP0721FT6P-UL Service Manual page 353

Table of Contents

Advertisement

No.
Part
1. Detachment
5
Coil-PMV
1) Perform work of procedure 1. -1) (Electrical
2) Cut the binding band as appropriate and
3) Disconnect the PMV wire connector from
4) Remove the Coil-PMV.
2 Attachment
1) Fix the Coil-PMV assembly as before.
2) Connect the wires disconnected as before.
3) Attach the binding band (locally procured)
4) Attach the electrical control box cover and
6
BUSHING
1. Detachment
1) Perform work of procedure 1. of 1 Detach-
2) Remove the bushing from the electrical
2 Attachment
1) Attach the bushing to the electrical control
2) Attach the electrical control box cover.
Work procedure
control box cover) and 4. -1) (Top plate).
remove the PMV wire from the wire clamp.
the control P.C. board.
Rotate the Coil-PMV to lock the Body-PMV
by mating the protrusions of the Body-PMV
with the holes in the Coil-PMV.
When performing this task, the Coil-PMV
should have the wires facing inward.
Hole
Protrusion
and wire clamps to the PMV wires as before.
the top plate. (Refer to 1. -2) and 4. -2))
ment. (Electrical control box cover)
control box.
box.
Push the bushing to set its groove to steel
sheet certainly.
(Refer to 1. of 2 Attachment)
- 353 -
Remarks
Binding band
(ex. RBM-Y6011FU4PUL )
PMV wire direction
Inside
Rotate
Groove
Wire clamp
Lock

Advertisement

Table of Contents
loading

Table of Contents