(8) If spacers (②) are damaged, replace it and attach collars(④) and bushes(③) to the service P.C. board(①).
(9) Attach the Capacitor P.C. board with the five screws(⑦:5pcs (M3) ) removed in step (5).
(10) Attach the reactor lead wire using the 2 or 4 screws removed in step (4) (⑥:2 or 4 pcs (M5) ).
For the model has REACTOR 2, be careful not to make a mistake in the combination of lead wires.
Notes:The screws are loose, the connection part will heat up and cause a malfunction.
Do not use electric drivers or air drivers.
(11) Attach the BUS-BAR and lead wires removed in step (3) with 6 screws(⑤:6pcs (M6) ).
Notes:The screws are loose, the connection part will heat up and cause a malfunction.
Do not use electric drivers or air drivers.
(12) Reconnect the connector. Connect correctly and securely.
(13) If the components on the P.C. board were bent during board replacement, adjust it manually ensuring
that it is not short or contact other parts.
(14) Attach the cover, turn on the power, and check the operation.
①P.C. board
The torque of the screws
⑤
Screw terminal
⑥
Screw terminal
⑦
Collar and bush
- 344 -
③Bush
④Collar
M6 x 0.47" (12mm)
M5 x 0.4" (10mm)
M3 x 0.98" (25mm)
2.21 ft•lbs (3.0 N•m)
1.48 ft•lbs (2.0 N•m)
0.44 ft•lbs (0.6 N•m )