How To Operate System While Troubled Outdoor Unit Being Repaired - Toshiba MMY-MUP0721FT6P-UL Service Manual

Table of Contents

Advertisement

10-2. How to Operate System While Troubled Outdoor Unit Being Repaired

<Outline>
After refrigerant is recovered from the troubled outdoor unit through a reclaim operation, the overall amount of
refrigerant held by the system becomes excessive, and this makes it impossible to operate the remaining
outdoor units even though they are not troubled. However, operation is still possible if the system-wide amount
of refrigerant is adjusted in accordance with the procedure described below.
<Work procedure>
(1) Follow the steps specified in "10-1. Refrigerant Recovery from Troubled Outdoor Unit (Reclaim)".
(2) Adjust the amount of refrigerant held by the system by removing some of it using a refrigerant recovery
device, etc.
Determine the amount of refrigerant to be removed according to the capacity of the failed outdoor unit. (See
the table below.)
Example: If you are under repairing of a 14ton (capacity type 168) outdoor unit in 42ton (capacity type 504) system
(combination of outdoor unit: 14ton + 14ton + 14ton):
Amount of refrigerant to be removed from this system = 4.4 Ibs
(3) Set up the outdoor unit from which refrigerant has been recovered in the manner described in "9-3. Outdoor
Unit Backup Operation Setting".
This completes the procedure.
Standard
Outdoor unit
capacity type
6ton
072
8ton
096
10ton
120
12ton
144
14ton
168
16ton
192
16ton
192
18ton
216
20ton
240
22ton
264
24ton
288
26ton
312
28ton
336
30tton
360
32ton
384
34ton
408
36ton
432
38ton
456
40ton
480
42ton
504
High heat
Outdoor unit
capacity type
6ton
072
8ton
096
10ton
120
12ton
144
16ton
192
20ton
240
24ton
288
30ton
360
Combination outdoor units
Unit1
Unit2
Unit3
072
096
120
144
168
192
072
072
144
072
144
096
168
096
144
144
168
144
168
168
168
096
096
144
144
096
168
144
096
168
168
096
168
144
144
168
168
144
168
168
168
Combination outdoor units
Unit1
Unit2
Unit3
072
096
120
072
072
096
096
120
120
096
096
096
120
120
120
- 297 -
Amount of additional
refrigerant(lbs)
2.2
2.2
0.0
2.2
4.4
5.5
4.4
4.4
4.4
6.6
4.4
6.6
8.8
8.8
6.6
8.8
11.0
8.8
11.0
13.2
Amount of additional
refrigerant(lbs)
2.2
2.2
6.6
4.4
4.4
13.2
6.6
19.8
Amount of additional
refrigerant(kg)
1.0
1.0
0.0
1.0
2.0
2.5
2.0
2.0
2.0
3.0
2.0
3.0
4.0
4.0
3.0
4.0
5.0
4.0
5.0
6.0
Amount of additional
refrigerant(kg)
1.0
1.0
3.0
2.0
2.0
6.0
3.0
9.0

Advertisement