Maintenance

WARNING
Daily
Inspect the trough area for any dirt or debris.
Inspect the air and blast hoses for damage such as cuts, kinks, or deformation.
Inspect fittings on the applicator and the machine for loose or improper connections and
correct as necessary.
Inspect applicator control cable for wear or improper connections and correct as necessary.
Inspect the applicator for any damage or loose parts and correct as necessary.
Weekly
Inspect the inside of the trough for dirt and inspect slicer blades for cracks, gouges, or broken
surfaces.
Verify the nozzle airflow exit end is not deformed or burred
Every 250 Hours or 12 Months
Replace the shaver blades every 250 hours or sooner in the event damage can be seen to one
or more of the blades.

Troubleshooting

Problem
Machine does not start
Click to go to Top of Document
Prior to any maintenance or inspection procedures, ensure that the
machine is turned off and the power source is disconnected.
Follow all
Lockout Tagout
Ensure that the air supply is closed, bled off, and the air supply hose is
disconnected from the machine.
Possible Reason
Machine's power cord is not plugged into
properly grounded electrical outlet.
Power switch is in the off position.
procedures.
Connect power cord to properly
grounded outlet
On control panel, press the power
switch once to turn ON the
machine
If problem is still not resolved
Contact Cold Jet for support
40
Solution
2023-08-29