Maintenance
WARNING
Daily
Inspect the trough area for any dirt or debris.
•
Inspect the air and blast hoses for damage such as cuts, kinks, or deformation.
•
Inspect applicator control cable for wear or improper connections and correct as necessary.
•
Inspect the applicator for any damage or loose parts and correct as necessary.
•
Weekly
Verify the nozzle airflow exit end is not deformed or burred.
•
Biannual
Inspect the power cord for damage.
•
Inspect the static bonding cable for damage.
•
Troubleshooting
Problem
Machine's power cord is not plugged in.
Power switch is in the off position.
Machine does
not start
The switch on the applicator is set to Air-Only
(I) mode.
Machine
Trough door is open
blasts air but
not dry ice
Using extended lengths of blast hose
Click to go to Top of Document
Prior to any maintenance or inspection procedures, ensure that the
machine is turned off and the power source is disconnected.
Follow all
Lockout Tagout
Ensure that the air supply is closed, bled off, and the air supply hose is
disconnected from the machine.
Possible Reason
procedures.
Connect power cord to properly
grounded outlet.
On control panel, push the power
switch to the ON position
If problem is still not resolved
Cold Jet for support
Set the applicator to Air+Dry Ice (II)
mode
Close the trough door.
Make sure your feed rate and
compressed air supply is sufficient to
25
Solution
Contact