Meter and CT Clamp Installation
CT CLAMP
CLOSE UP
METER
DATASHEET
Incoming
Supply
Warranty
Limited Warranty Policy – APEX Series
i. Scope of Warranty
Plese see www.projectev.co.uk for warranty information.
CT clamp for solar or load
balancing gets installed
around the live cable from the
main fuse. The arrow points to
the flow of electricity, and
when solar is producing, the
CT clamp registers this as a
minus figure. This is how the
charger knows the difference
between mains and solar.
Please Note:
•
There is a fly lead of 3m.
•
If this is not installed correctly the
charger will not see solar generation.
•
Terminals (located on charger):
RS485A and RS485B
•
This needs to match with numbers 9
and 10 on the meter
L
CT Clamp
N
E
RS485 (Twisted Pair)
*Live and neutral required for
power of meter and voltage
reference.
*1 DIN meter to be installed
inside of the distribution board
Distribution
N
Board
Earth
Set upper limit to required value
L
EV
Charger
E
19