EWM Drive XQ AC Operating Instructions Manual page 47

Wire feed unit
Hide thumbs Also See for Drive XQ AC:
Table of Contents

Advertisement

Error 56: Mains phase failure
 One phase of the mains voltage has failed.
Check the mains connection, mains plug and mains fuses.
Error 57: Slave tacho error
Category B
 Fault in the wire feeder (slave drive).
Check the connections (connectors, lines).
 Permanent overload of the wire drive (slave drive).
Do not lay the liner in tight radii.
Check the liner for ease of movement.
Error 58: Short circuit
Category B
 Short circuit in the welding circuit.
Eliminate the short circuit in the welding circuit.
Place the welding torch on an insulated surface.
Error 59: Incompatible machine
 A machine connected to the system is not compatible.
Disconnect the incompatible machine from the system.
Error 60: Incompatible software
 The software of a machine is not compatible.
Disconnect the incompatible machine from the system
Request service.
Error 61: Welding monitoring
 The actual value of a welding parameter is outside the specified tolerance range.
Maintain the tolerance ranges.
Adjust the welding parameters.
Error 62: System component
 The system component was not found.
Request service.
Error 63: Mains voltage error
 Operating and mains voltage are incompatible.
Check or adjust the operating and mains voltage.
[1]
only Picotig 220 pulse
[2]
See technical data for values and other switching thresholds > see 8 chapter.
099-005613-EW501
05.12.2023
Rectifying faults
Error messages (power source)
47

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Drive XQ AC and is the answer not in the manual?

Questions and answers

Table of Contents