EWM Drive XQ AC Operating Instructions Manual page 45

Wire feed unit
Hide thumbs Also See for Drive XQ AC:
Table of Contents

Advertisement

Error 26: Excess pilot arc module temperature
Category A
 The power source is overheating.
Allow the switched-on machine to cool.
 Fan is blocked, dirty or faulty.
Check the fan and clean or replace.
 Air inlet or outlet is blocked.
Check the air inlet and outlet.
Error 32: Error I>0
 Current recording is faulty.
Request service.
Error 33: Error UIST
 Voltage recording is faulty.
Eliminate the short circuit in the welding circuit.
Remove the external sensor voltage.
Request service.
Error 34: Electronics error
 A/D channel error
Switch the machine off and on.
Request service.
Error 35: Electronics error
 Slope error
Switch the machine off and on.
Request service.
Error 36:
error
conditions violated.
Switch the machine off and on.
Request service.
Error 37: Excess temperature / electronics error
 The power source is overheating.
Allow the switched-on machine to cool.
 Fan is blocked, dirty or faulty.
Check the fan and clean or replace.
 Air inlet or outlet is blocked.
Check the air inlet and outlet.
Error 38: Error IIST
 Short circuit in the welding circuit before welding.
Eliminate the short circuit in the welding circuit.
Request service.
Error 39: Electronics error
 Secondary overvoltage
Switch the machine off and on.
Request service.
099-005613-EW501
05.12.2023
Rectifying faults
Error messages (power source)
45

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Drive XQ AC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents