Operating manual Piston Pump EvoMotion 5-60
8   Cleaning and Maintenance
1. Check hoses, pipes, and couplings every day and replace if necessary.
2. Before every commissioning, check all connections for leaks.
3. Additionally, the operator must regularly check the complete hoses for wear and tear as
well as for damage at intervals that he/she has set. Records of these checks must be
kept.
4. Replace the complete hose if one of the following two periods is exceeded:
4 6 years from the date of the hose crimping (see fitting embossing).
4 10 years from the date of the hose imprinting.
Fitting embossing
(if present)
xxx bar
yymm
XX
Hose imprinting
WAGNER
yymm
xxx bar (xx MPa) e.g. 270 bar (27MPa)
XX
DNxx (e.g., DN10)
8.2.6   Emptying Pump
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ignition of potentially explosive surrounding atmosphere.
4 Empty and fill the device slowly and in a controlled manner.
4 Avoid potentially explosive atmosphere in the surroundings.
Info
If the pumping product becomes heated, switch off all heaters and let the product cool
off.
Order number 2333563 | Edition 10/2020
Meaning
Pressure
Crimping date (year/month)
Internal code
Meaning
Name / manufacturer
Date of manufacture (year/month)
Pressure
Internal code
Nominal diameter