WAGNER EvoMotion 5-60 Translation Of The Original Operating Manual page 32

Piston pump
Table of Contents

Advertisement

Operating manual Piston Pump EvoMotion 5-60
6   Assembly and Commissioning
1. Secure spray gun with safety lever.
2. Check the permissible pressures.
3. Check all connections for leaks.
4. Check hoses for damage in accordance with chapter Safety Checks and Maintenance
Intervals [8 39].
5. Fill the separating agent in accordance with Chapter Filling with Separating Agent
[8 40].
6.7.2   Fill the Pump with Flushing Agent
The devices are tested during manufacturing with emulsifying oil, pure oil or solvent.
Possible residues must be flushed out of the circuits with a solvent (flushing agent) before
commissioning.
4 Fill the empty device with flushing agent in accordance with Chapter Filling the Empty
Pump [8 43].
6.7.3   Pressure Tightness Test
WARNING
Overpressure!
Risk of injury from bursting components.
4 The operating pressure must not exceed the value shown on the type plate.
1. Gradually increase the pressure in pump with the pressure regulator until maximum
pressure is reached. Maintain the pressure for 3 minutes and check all connection
points for leaks.
2. Carry out pressure relief in accordance with Chapter Pressure Relief / Work Interruption.
6.7.4   Verifying a Safe Operational Condition
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4 Carry out safety checks in accordance with Chapter Safety Checks and Maintenance
Intervals [8 39].
6.7.5   Filling with Working Product
4 Proceed in accordance with Chapter Filling the Empty Pump [8 43].
32
Order number 2333563 | Edition 10/2020

Advertisement

Table of Contents
loading

Table of Contents