Operating manual Piston Pump EvoMotion 5-60
6   Assembly and Commissioning
2
3
1
8
4
7
1
Pump
2
Pressure regulator
3
Spray gun
4
Return tube
1. Mount pump (1) on wall mount or trolley (6).
2. With an AirSpray system, fit the air hose on the spray gun and on the air line (cleaned
compressed air).
3. Fit suction system (7).
4. Mount the return valve (8) for pressure relief or product circulation.
5. Mount return tube (4) or return hose.
6. Connect a suitable product shut-off valve or spray gun (3) in accordance with the spray
gun operating manual.
6.5.1   Ventilation of the Spray Booth
– Operate the device in a spray booth approved for the respective working materials.
- or -
– Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
– Observe national and local regulations for the exhaust air speed.