8   Cleaning and Maintenance
Weekly
1. Check system for damage.
2. Check that the safety fixtures function properly (see Chapter Protective and Monitoring
Equipment [8 19]).
Yearly or as required
1. In accordance with DGUV regulation 100-500, Chapters 2.29 and 2.36:
4 Have the liquid ejection devices checked by an expert (e.g. WAGNER service
technician) as required, but no later than every 12 months to ensure that they are in
safe working order.
4 For shut down devices, the examination can be suspended until the next start-up.
8.2.4   Filling with Separating Agent
NOTICE
Piston pump dry run
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
4 Ensure that the separating agent tank is filled with sufficient separating agent.
B_04146
Pour the supplied separating agent into the separating agent container.
Filling level: 2 cm; 0.8 inch under the filling opening.
Separating agent: order no. 9992504
Inclination angle of the pump
Maximum permissible inclination of pump for moving, transportation etc. after filling with
separating agent is ± 30°. The pump must be vertical during operation.
8.2.5   Product Hoses, Pipes and Couplings
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.