WAGNER EvoMotion 5-60 Translation Of The Original Operating Manual page 39

Piston pump
Table of Contents

Advertisement

Operating manual Piston Pump EvoMotion 5-60
8   Cleaning and Maintenance
A skilled person must ensure that the device is checked for being in a reliable state after
maintenance work is completed.
8.2.2   Maintenance Instructions
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
4 Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
4 Use only WAGNER original spare parts and accessories.
4 Only repair and replace parts that are listed in the spare parts chapter and that are
assigned to the device.
4 Before all work on the device and in the event of work interruptions:
4 Relieve the pressure from the spray gun, product hoses and all devices.
4 Secure the spray gun against actuation.
4 Switch off the energy and compressed air supply.
4 Disconnect the control unit from the mains.
4 Observe the operating and service manual for all work.
Prior to maintenance
It should be ensured that the device is in the following state before carrying out any work on
it:
– Flush and clean the system according to Chapter Decommissioning and Cleaning
[8 38].
– Interrupt the air supply.
After maintenance
– Carry out safety checks in accordance with Chapter Safety Checks and Maintenance
Intervals [8 39].
– Put the system into operation and check for leaks as described in Chapter
Commissioning [8 31].
– Have the system checked for safe condition by a skilled person.
– Carry out functional check in accordance with Chapter Function Test after Repair Work
[8 48].
8.2.3   Safety Checks and Maintenance Intervals
Every day
1. Check grounding: see Chapter Grounding [8 29].
2. Check hoses, tubes and couplings: see Chapter Product Hoses, Pipes and Couplings
[8 40]
3. Check the level of separating agent in the separating agent tank and top up, if
necessary, in accordance with chapter Filling with Separating Agent [8 40].
4. For each decommissioning, the process according to Chapter Decommissioning and
Cleaning [8 38] must be followed.
5. If the pump has to be emptied for maintenance work, proceed according to Chapter
Emptying Pump [8 41].
Order number 2333563 | Edition 10/2020
39

Advertisement