Canon NP6012 Service Manual page 198

Hide thumbs Also See for NP6012:
Table of Contents

Advertisement

MI MECHANICAL SYSTEM
Fixing
screw
Figure 4-711
5) After making the adjustment, tighten the
adjusting rol! fixing screw to fix the roll in
place.
6)
Turn off the power switch, and measure
the position of the fixing film from the
front side plate of the fixing assembly.
The standard is 13 to 17 mm; if it is out-
side the standard, replace the upper fix-
ing unit.
Fixing film
frame
Figure 4-712
4-48
COPYRIGHT © 1995 CANON INC.
Front side
13 to 17 mm
4.
Removing the Lower Fixing Roller
1) Open the copier's top unit.
2)
Remove the delivery roller.
(See "1. Removing the Delivery Roller'
under "E. Delivery Assembly.")
3) While disengaging the four claws @,
remove the lower fiting roller unit @.
Figure 4-713
4)
Remove
the two springs @ and two
bushings @, and remove the lower fixing
roller © and the inlet guide ©.
® ®
®
©
® ©
Figure 4-714
CANON NP6O12/NP6O12F/NP6212 REV SEPT. 1995 PRINTEDIN JAPAN (MPRIME
AU JAPON)