Canon NP6012 Service Manual page 130

Hide thumbs Also See for NP6012:
Table of Contents

Advertisement

www
SSS
SS
OPERATIONS AND TIMING
1) Turn on the copier.
2) Short the two jumper wires (JP3, JP4)
3)
4)
COPYRIGHT © 1995 CANON INC.
on the DC control PCB with a screwdriv-
er,
* The ratio/count indicator indicates 'F'.
Figure 3-803
Stop shorting the jumpers; then, using
the +/- key, bring
up '40' on the
ratio/count indicator, and press the Start
key.
¢ The scanning lamp will turn on, and
the main motor (M1) will start to rotate.
Turn VR103 on the DC controller PCB
fully clockwise.
VR103
Figure 3-804
5}
6)
7)
8)
CANON NP6O12/NPGO12F/NP6212 REV.1 SEPT. 1995 PRINTED IN JAPAN (IMPRINE
AU JAPON)
Place a newspaper on the copyboard,
and close the copyboard cover.
Adjust VR102 so that the indication in
the display is b2 through bc.
VR102
Figure 3-805
Remove the newspaper from the copy-
board, and place a stack of five sheets
of copy paper on the copyboard glass in
its place; then, close the copyboard
glass.
Adjust VR103 on the DC controller PCB
so that the indication on the control
panel is 53 through 5d.
VR103
o
ae
WP
—$
>
Figure 3-806
3-85