Maintenance Schedule (General)
Verification
For units with an interlock, the lift should not
move if any door is not closed and locked. For
units with a GAL lock, the lift should not move if
any door is not closed.The lift should not move
beyond the door zone (usually less than four
inches away from the landing in either
direction) if the door is not locked.
Verify the underpan is working. Be sure to
insert the shoring pins.
Verify correct operation of the phone (where
applicable).
Confirm doors or gates are all self-closing.
Check that the Stop button works correctly
M2LIFT Owner's Manual
Frequency
(Commercial/
Exterior)
Every 6
months
Every 6
months
Every 6
months
Every 6
months
Every 6
months
Part No. 001103, 30-m01-2024
Frequency
(Residential)
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months