5. TROUBLESHOOTING

Only qualified technicians are authorized to perform
repairs and maintenance. DO NOT manipulate, modify or
remove any safety feature of the lift. If any issues persist,
please contact your authorized Savaria Dealer
Potential Problem
Platform goes up but does not
come down
Platform comes down but does
not go up
Platform does not move
M2LIFT Owner's Manual
WARNING
Possible Solution
Check the underpan sensors. Pull down on the
underpan to ensure the pan is not stuck in the
activated position.
Check that the power cord is plugged in.
Check that the key is ON.
Check that the gate is closed.
Check to see if the Emergency Stop buttons (on
the COP and tower) are pushed in; they must be
pulled out for normal operation.
If the platform is at the top landing, check the
underpan sensors as described above.
Check that the power cord is plugged in.