Fault code display:
Fault Code
60
Power feedback protection
71
Firmware version inconsistent
72
Current sharing fault
80
CAN fault
81
Host loss
82
Synchronization loss
83
Battery voltage detected different
84
AC input voltage and frequency detected different
85
AC output current unbalance
86
AC output mode setting is different
When the units are operated in 3-phase
application, please choose "3PX" to define
L1 phase:
each inverter.
It is required to have at least 3 inverters or
maximum
equipment. It's required to have at least one
inverter in each phase or it's up to
in one phase. Please refers to 5-2 for detailed
information.
L2 phase:
Please select "3P1" in program 28 for the
inverters connected to L1 phase, "3P2" in
program 28 for the inverters connected to L2
phase and "3P3" in program 28 for the
inverters connected to L3 phase.
L3 phase:
Be sure to connect share current cable to units
which are on the same phase.
Do NOT connect share current cable between
units on different phases.
Fault Event
44
8
inverters to support three-phase
Icon on
six
inverters