Table 3 Charge Mode Specifications
Utility Charging Mode
INVERTER MODEL
Charging Current
@ Nominal Input Voltage
Flooded
Bulk
Battery
Charging
AGM / Gel
Voltage
Battery
Floating Charging Voltage
Overcharge Protection
Charging Algorithm
Charging Curve
Solar Charging Mode (MPPT type)
INVERTER MODEL
Rated Power
Maximum charging current
Efficiency
Max. PV Array Open Circuit
Voltage
PV Array MPPT Voltage Range
Battery Voltage Accuracy
PV Voltage Accuracy
Charging Algorithm
Joint Utility and Solar Charging
Max Charging Current
Default Charging Current
OG-Plus 3.24RM
Default: 30A, max: 60A
29.2Vdc
28.2Vdc
27Vdc
34Vdc
Battery Voltage, per cell
2.43Vdc (2.35Vdc)
2.25Vdc
T1 = 10* T0, minimum 10mins, maximum 8hrs
Bulk
(Constant Current)
(Constant Voltage)
OG-Plus 3.24RM
1500W
60A
30~115Vdc
120A
31
OG-Plus 3.48RM
58.4Vdc
56.4Vdc
54Vdc
66Vdc
3-Step
Absorption
Maintenance
(Floating)
OG-Plus 3.48RM
4000W
80A
98.0% max.
145Vdc
60~115Vdc
+/-0.3%
+/-2V
3-Step
140A
60A
OG-Plus 5.48RM
Default: 30A,
max: 80A
Charging Current, %
Voltage
100%
50%
Current
Time
OG-Plus 5.48RM
4000W
80A
60~115Vdc
160A