35
Battery equalized time
36
Battery equalized timeout
37
Equalization interval
Equalization activated
39
immediately
Reset all stored data for PV
40
generated power and
output load energy
Firmware upgrade for USB
41
On-the-Go function
Re-write USB internal
42
parameter
43
Export data log function
93
Erase all data log
Data log recorded interval
*The maximum data log
94
number is 1440. If it's over
1440, it will overwrite as
first log.
95
Time setting – Minute
60min (default)
120min (default)
30days (default)
Enable
If equalization function is enabled in program 33, this program
can be set up. If "Enable" is selected in this program, it's to
activate battery equalization immediately and LCD main page
will shows "
". If "Disable" is selected, it will cancel
equalization function until next activated equalization time
arrives based on program 37 setting. At this time, "
not be shown in LCD main page.
Not reset(Default)
Upgrade disable (Default)
Re-write function disable
(Default)
Export log function disable
(Default)
Reset log function disable
3 minutes
10 minutes(default)
30 minutes
20
Setting range is from 5min
to 900min. Increment of
each click is 5min.
Setting range is from 5min
to 900 min. Increment of
each click is 5 min.
Setting range is from 0 to 90
days. Increment of each
click is 1 day
Disable (default)
" will
Reset
Upgrade enable
RE-write function enable
Export log function enable
Reset log function enable
5 minutes
20 minutes
60 minutes
For
minute
setting,
range is from 00 to 59.
the